3D OCT-2000

Download Brochure

Download

Features

  • High resolution fundus image
  • High resolution b-scan image
  • Easy to use high quality touch screen
  • Normative database
  • Glaucoma module
  • Auto focus, Auto shoot
  • Full network support
  • IMAGEnet i-base connection

3D OCT-2000

Description

Topcon’s 3D imaging and analysis functions provide invaluable pathological confirmation of progression. With the addition of noise reducing algorithms and Infra red/3D tracking technology, the Topcon 3D OCT-2000 provides you with extremely detailed OCT scans. 

Fundus Images
Unique to the Topcon OCT series is its integrated retinal photography function, which is based upon its highly successful non-mydriatic fundus camera. An interchangeable (future proof) 16.2mp digital camera acquires highly detailed images using a sub one millisecond flash at the point of OCT capture or stand alone fundus photography if required. 

Glaucoma
One of many modules within Topcon’s Fastmap software; The Glaucoma module allows fully automated disc topography, normative database comparison and total progression analysis (trend analysis) through various screening options. Complemented by Ganglion cell analysis and anterior chamber angle measurements the glaucoma module is a comprehensive screening tool.  

Anterior segment scanning
By combining both OCT scan technology with traditional photographic imaging a variety of analysis functions and scan protocols allow for the detection and treatment of many corneal conditions. Full corneal thickness topography and automated central thickness values are complemented by corneal curvature topography along with high resolution imaging.

Case study
The website "Retina Revealed," publishes a weekly, thought-provoking series providing doctors/clinicians with the latest technology in Retina via online case presentations. 
In this case the Topcon 3D OCT-2000 reveals the actual location and third dimensional extent of a subhyaliod hemorrhage, a micro-aneurysm and disc neovascularisation. 

Specifications

  • Observation & photography of fundus  
    Picture angle 45°
    Operating distance 40.7mm (in fundus photography) and 63.7mm (in anterior segment photography)*
    Photographable diameter of pupil  
    Retinal camera 45°: Ø 4.0mm; smaller pupil diameter: Ø 3.3mm or more
    Optical Coherence Tomography Ø 2.5mm or more
    Observation & photography of fundus / Anterior segment tomogram  
    Scan patterns (Recommended) **  
    Macular: 3D Scan 512×128 ( 128 horizontal scan lines comprised of 512 A-scans ), 6×6mm
    Macular: Radial Scan 1024×6 or 12 ( 6 or 12 radial scan lines comprised of 1024 A-scans ), 6mm
    Disc: 3D Scan 512×128 ( 128 horizontal scan lines comprised of 512 A-scans ), 6×6mm
    Disc: Circle Scan ø3.4mm, 1024 A-scans
    7 Line Raster 4096 A-scans per B-scan, 6mm
    Scan speed 50,000 A-scans per second
    Scanning range (On Fundus) 8.2×3mm, 6×6mm, 4.5×4.5mm, 3×3mm
    (On Cornea)* 6×6mm, 3×3mm
    Lateral resolution <20μm
    In-depth resolution 5 μm~6 μm
    Observation & photography of Fundus Image / Fundus Tomogram  
    Internal fixation target Matrix LCD (The display position can be changed and adjusted. The presenting method can be changed.)
    Power source / supply  
    Power source Voltage 100/110/120/220/230/240V
      Frequency 50-60Hz
    Power supply 200VA (max 400VA)
    Dimensions / weight  
    Dimensions W545 × D535 × H600-630 mm
    Weight 35 kg
      *With anterior segment attachment.
      **More variable scan patterns available with a combination of different pixel and scan range.

     

Share this product

Copyright © 2014 || National Trading Syndicate Ltd.