3D OCT-2000 FA plus, Optical Coherence Tomography

Download Brochure

Download

Features

Key Features

  • The ultimate all-in-one OCT
  • High resolution OCT
  • High resolution colour fundus image
  • High resolution FA & FAF images
  • Intuitive workflow
  • Normative database
  • Glaucoma module
  • Full network support
  • IMAGEnet i-base connection

3D OCT-2000 FA plus, Optical Coherence Tomography

Description

The Topcon 3D OCT-2000 FA plus is the ultimate all-in-one OCT for OCT scan, FA images, FAF images, colour fundus images and red-free images. All these images can be generated from a single device.
Topcon's 3D imaging and analysis functions provide invaluable pathological confirmation of progression. With the addition of noise reducing algorithms and Infra red/3D tracking technology, the 3D OCT-2000 FA plus provides you with extremely detailed OCT images. Single scans, but also 3D and 2D OCT images.

OCT scans
The enhanced 50.000 A-scans/sec allows for faster tomography acquisition and minimises artifacts generated by eye movements, producing clear cross-sectional retinal images. The new analysis mode reduces processing time. Topcon's "Enhanced Choroidal Mode" visualises further internal structures, allowing much superior visualisation of the RPE and choroidal area.

Fundus Images
Unique to the Topcon OCT-2000 FA plus is its integrated retinal photography function for colour, red-red free, FA and FAF images. An interchangeable 16.2mp digital camera acquires highly detailed images using a sub one millisecond flash at the point of OCT capture or stand alone fundus photography if required.

Glaucoma
One of many modules within Topcon's Fastmap software; The Glaucoma module allows fully automated disc topography, normative database comparison and total progression analysis (trend analysis) through various screening options. Complemented by Ganglion cell analysis and anterior chamber angle measurements the glaucoma module is a comprehensive screening tool.

Anterior segment scanning
By combining both OCT scan technology with traditional photographic imaging a variety of analysis functions and scan protocols allow for the detection and treatment of many corneal conditions. Full corneal thickness topography and automated central thickness values are complemented by corneal curvature topography along with high resolution imaging.

Specifications

  • Specifications

    Scan Mode Color, FA*1, FAF*1 (Spaide Filters), Red-free*2
    Observation Near IR
    Picture Angle 45°
      Equivalent 30° (Digital Zoom)
    Diopter Scale Range*3 -13 D to +12 D (in fundus photography)
    Operating Distance 40.7 mm (in fundus photography)
      63.7 mm (in anterior segment photography)*4
    Photographable Diameter of Pupil 45°: ø 4.0 mm or more
      Small pupil diameter: ø 3.3 mm or more
    Scanning Range | (On Fundus) [Lateral] within 3~9mm [Vertical] within 3~9mm
    Scanning Range | (On Cornea) [Lateral] within 3~6mm [Vertical] within 3~6mm
    Scan Patterns*5 | Macula: 3D Scan 512x128 (128 horizontal scan lines comprised of 512 A-scans), 6 x 6 mm
    (Recommended) | Macula: Radial Scan 1024x6 or 12 (6 or 12 radial scan lines comprised of 1024 A-scans), 6 mm
    (Recommended) | Macula: 7 Line Raster 1024x7 (1024 A-scans per B-scan x7), 6 mm
    (Recommended) | Disc: 3D Scan 512x128 (128 horizontal scan lines comprised of 512 A-scans), 6 x 6 mm
    (Recommended) | Disc: Circle Scan 1024 A-scans, ø 3.4 mm
    (Recommended) | Anterior: Radial Scan (For Cornea) 1024x12 (12 radial scan lines comprised 1024 A-scans), 6 mm
    (Recommended) | Anterior: Line Scan (For Angle Chamber) 1024 (line scanline comprised of 1024 A-scans), 3 mm
    Scan Speed 50,000 A-scans per second
    Scan Depth 2.3 mm
    In-depth Resolution 5 µm ~ 6µ
    Photographable Diameter of Pupil ø 2.5 mm or more
    Retinal Layers Identified Macula: ILM, IS/OS, RPE, BM
      Glaucoma: ILM, NFL, IPL
    OCT Reference Focus Vitreous and Choroid
    Fixation Adjustable internal matrix LCD and external fixation device
      (Matrix LCD: The display position can be changed and adjusted. The presenting method can be changed.)
    Light Source Super luminescence distance diode (SLD)
      Wavelenght: 840nm
      Half Bandwidth: 50nm
      Output on cornea ~ 0.65 mW
    Power Source Voltage: 100/110/120/220/230/240V
      Frequency: 50-60Hz
    Power supply 200VA (Max 400VA)
    Dimensions 545 mm(W) x 535 mm(D) x 600 ~ 630 mm(H)
    Weight 35 kg (3D OCT-2000)
      37 kg (3D OCT-2000 FA Plus)
      *1 Only for FA Plus model
      *2 Display digital Red-free
      *3 Without the diopter compensation
      *4 With anterior segment attachment
      More variable scan patterns available with a combination of different pixel and scan range

     